* Add Philips Moonlight Bedside Lamp support
* Update comment
* Make hound happy
* Wrap the call that could raise the exception only
* Remote blank line
* Use updated python-miio API
* Set lock status correctly for Schlage BE469 Z-Wave locks
PR #17386 attempted to improve the state of z-wave lock tracking for
some problematic models. However, it operated under a flawed
assumptions. Namely, that we can always trust `self.values` to have
fresh data, and that the Schlage BE469 sends alarm reports after every
lock event. We can't trust `self.values`, and the Schlage is very
broken. :)
When we receive a notification from the driver about a state change,
we call `update_properties` - but we can (and do!) have _stale_
properties left over from previous updates. #17386 really works best
if you start from a clean slate each time. However, `update_properties`
is called on every value update, and we don't get a reason why.
Moreover, values that weren't just refreshed are not removed. So blindly
looking at something like `self.values.access_control` when deciding to
apply a workaround is not going to always be correct - it may or may not
be, depending on what happened in the past.
For the sad case of the BE469, here are the Z-Wave events that happen
under various circumstances:
RF Lock / Unlock:
- Send: door lock command set
- Receive: door lock report
- Send: door lock command get
- Receive: door lock report
Manual lock / Unlock:
- Receive: alarm
- Send: door lock command get
- Receive: door lock report
Keypad lock / Unlock:
- Receive: alarm
- Send: door lock command get
- Receive: door lock report
Thus, this PR introduces yet another work around - we track the current
and last z-wave command that the driver saw, and make assumptions based
on the sequence of events. This seems to be the most reliable way to go
- simply asking the driver to refresh various states doesn't clear out
alarms the way you would expect; this model doesn't support the access
control logging commands; and trying to manually clear out alarm state
when calling RF lock/unlock was tricky.
The lock state, when the z-wave network restarts, may look out of sync
for a few minutes. However, after the full network restart is complete,
everything looks good in my testing.
* Fix linter
* Automatically detect if ipv4/ipv6 is used for cert_expiry
Fixes#18818
Python sockets use ipv4 per default. If the domain which should be checked
only has an ipv6 record, socket creation errors out with
`[Errno -2] Name or service not known`
This fix tries to guess the protocol family and creates the socket
with the correct family type
* Fix line length violation
* Fix unavailable
Change setting to unavailable when getting request exceptions only after 1 minute has past since 1st occurrence.
* Put common code in _check_state_available
Put common code to determine if available should be set to False in method _check_state_available
* Unique ID support
New unique ID support, based on hub's serial number and device's permanent ID
* Fixes, showing attributes
Minor fixes
Showing room, hub, fibaro_id for easier mapping and finding of devices
* Update fibaro.py
* Add support for multiple RainMachine controllers
* Member comments
* Member comments
* Member comments
* Cleanup
* More config flow cleanup
* Member comments